Loading...
 

search results for ""

https://mdc.olympus.eu/rendition/084438885177/ad8ebd43f74f578f94faa2e33630f412/-FPNG-B2024

Luminal Patency

Biliary Stents

Single-use Hilar Biliary Uncovered Stents (NNN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Large cell structure on the whole length of the stent to facilitate second stent placement with the stent-through-stent technique
  • Reduced stent migration supported by flared ends
  • Delivery device reloadable



Single-use Hilar Biliary Uncovered Stents (NNN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 16 gold radiopaque markers
  • Large cell structure in the middle part of stent to facilitate second stent placement with the stent-through-stent technique
  • Reduced stent migration supported by flared ends
  • Delivery device not reloadable



Single-use Hilar Biliary Uncovered Stents (NNN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Thin, dedicated delivery device for simultaneous side-by-side stenting
  • For simultaneous side-by-side stenting, a working channel of minimum 4.2 mm is required
  • Stent can be recaptured



Single-use biliary covered stents with flaps (CCC)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers on the stent’s mesh and on every second anchoring flap (16 markers in total)
  • Reduced stent migration supported by four anchoring flaps on each end
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For malignant and benign indications
  • Delivery device reloadable



Single-use Biliary Covered Stents with Flaps (CCC) , TTS –
Distal Wire-guided, FAST™ Delivery System

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 radiopaque markers on the stent’s mesh
  • Reduced stent migration supported by two anchoring flaps on each end
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For malignant and benign indications
  • Stent can be recaptured



Single-use biliary covered stents with flaps (CCC) for percutaneous application

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers on the stent’s mesh and on every second anchoring flap (16 markers in total)
  • Reduced stent migration supported by four anchoring flaps on each end
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For percutaneous application
  • For malignant and benign indications
  • Delivery device reloadable



Single-use biliary covered stents with flaps (CCC)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers on the stent’s mesh and on every second anchoring flap (14 markers in total)
  • Reduced stent migration supported by four anchoring flaps on the distal end and a flared proximal end
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For malignant and benign indications
  • Delivery device reloadable



Single-use biliary covered stents with flaps and two lassos (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers on the stent’s mesh and on every second anchoring flap (14 markers in total)
  • Reduced stent migration supported by four anchoring flaps on the proximal end and a flared distal end
  • Short loop for repositioning and long proximal loop marked with a golden marker designed for inside-out removal
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For malignant and benign indications
  • Delivery device reloadable



Single-use biliary covered stents with one lasso (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Proximal lasso facilitates stent repositioning and removal
  • Reduced tissue ingrowth achieved by silicone inner covering
  • Reduced foreshortening compared to SHC
  • For malignant and benign indications
  • Stent can be recaptured



Single-use biliary covered stents (CCC) for percutaneous application

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For percutaneous application
  • Delivery device reloadable



Single-use biliary uncovered stents (NNN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Increased radial force and better conformity compared to SHS
  • Delivery device reloadable



Single-use Hilar Biliary Uncovered Stents for Percutaneous Application (NNN)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Delivery device reloadable



Single-use biliary uncovered stents (NNN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Stent can be recaptured



Single-use Biliary Uncovered Stents (NNN), TTS –
Distal Wire-guided, FAST™ Delivery System

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Stent can be recaptured



Single-use Hilar Biliary Uncovered Stents for Percutaneous Application (NNN)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Delivery device reloadable



Single-use biliary partially covered stents (NCN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 16 gold radiopaque markers
  • Reduced stent migration supported by uncovered flared ends
  • Delivery device reloadable



Single-use biliary partially covered stents (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends and uncovered proximal part
  • Delivery device reloadable



Single-use biliary covered stents (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Proximal loop for effortless stent repositioning and removal
  • Increased drainage efficiency supported by hybrid design with multiple holes in the silicone membrane
  • Delivery device reloadable



Single-use biliary covered stents (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Minimised leakage supported by large wheel design and full-length covering with silicone
  • Indicated for pancreatic drainage
  • Delivery device reloadable



Single-use biliary proximally covered stents with eight flaps, (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 16 gold radiopaque markers
  • Reduced stent migration supported by uncovered distal part and flaps
  • Delivery device reloadable